USING THE RADIO FREQUENCY IDENTIFICATION DEVICES (RFID)
Press the Reset Button (3) located inside the
case. Two "beeps" will sound (if the sound
is turned on) and panel will flash blue twice.
You will have 5 seconds to begin
programming a RFID device or you will have
to start over.
If you do not program the RFID device (card,
fob or sticker), the RFID, Red light will flash
and beep 3 times.
Center and place your access card, key fob,
or sticker on the RFID button
in FIGURE 1.
Two "beeps" will sound (if the sound is
turned on) and panel will flash green twice if
the device is recorded.
Press the reset button to confirm recorded
devices. Four "beeps" will sound (if the
sound is turned on) and panel will flash blue
four times if device is recorded. Repeat
above steps to record additional RFID
devices.
NOTE: Recording RFID devices does not
replace or remove other prerecorded
devices, or combinations.
Only 5 RFID devices can be recorded.
If an attempt is made to record a 6th device
the case will beep 3 times and the red light
will flash 3 times.
OPENING THE CASE USING RFID
Hold RFID device approximately ¼" over the
over RFID button
sound (if the sound is turned on) and the
panel will flash green twice and open.
If RFID is not programmed, the Red light will
flash and beep 3 times (if the sound is
turned on).
as shown
. Two "beeps" will
STICKER ON BACK
If an invalid RFID device is scanned 3 times
the case will beep 5 times (if the sound is
turned on) and the red light will flash 5
times resulting in the case being
automatically locked out for 60 seconds
before you can scan your device again.
The case will beep one time (if the sound is
turned on) and the green light will flash
once when the lockout period is over.
If an invalid RFID device is scanned 1
additional time, the case will beep 5 times
(if the sound is turned on) and the red light
will flash 5 times resulting in the case being
automatically locked out for 5 minutes
before the the scan can be tried again. The
case will beep one time (if the sound is
turned on) and the green light will flash
once when the lockout period is over.
The case may still be opened using the
supplied Key to override failed RFID scans.
To close the case, push the lid closed
until locked.