9
DEVICES WITH SPECIAL FEATURES
9
Devices with special features
10
Troubleshooting
12
Table 8: Sensing range setting
The sensor is adjusted and ready for operation.
4
Time function setting
WT34xx2x, WT34-xx5x: no time delay, t1 = time delay, t2 = time delay; for -R: 0 = relay
deactivated, 1 = relay active. Time delay selector switch can be set on the device according
to the following graphic.
Time stages: 0.5 ... 10 s can be adjusted.
0
+
1
2
Figure 7: Time functions
WT34-V210S01, WT34-R210S02: preset to dark switching
WT34-B400S04: preset to light switching, light spot size approx. Ø 15 mm (1 m)
WT34-R210S06: close range blanking (no detection between 0 and 80 mm)
WT34-R220S07: black cover between sender and receiver
The Troubleshooting table indicates measures to be taken if the sensor stops working.
0.5 ... 10 sec.
0.5 ... 10 sec.
0.5 ... 10 sec.
8009202.11O1 | SICK
Subject to change without notice