Dimensional Drawings - SICK WLA16 Instrucciones De Operación

Ocultar thumbs Ver también para WLA16:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 72
Supply voltage U
B
Ripple
Current consumption
Output current I
max.
Max. response time
Switching frequency
Enclosure rating
5)
Protection class
Circuit protection
Ambient operating temperature
1)
16 VDC to 30 VDC, without load
2)
10 VDC to 16 VDC, without load
3)
Signal transit time with resistive load in switching mode. Deviating values possible in COM2 mode.
4)
With a light/dark ratio of 1:1 in switching mode. Deviating values possible in IO-Link mode.
5)
Pursuant to EN 60529
6)
Replaces IP69 K pursuant to ISO 20653: 2013-03
7)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
8)
Do not bend cables below 0°C.
12.1

Dimensional drawings

8020348.14CS | SICK
Subject to change without notice
20
4,1
1
7,8
3
Ø 12,9
7,7
4
Figure 11: Dimensional drawing 1, cable
Center of optical axis
1
Fixing hole, Ø 4.1 mm
2
Connection
3
LED indicator green: Supply voltage
4
active
LED indicator yellow: Status of
5
received light beam
BluePilot blue: Alignment aid
6
WLA16P
DC 10 ... 30 V
≤ 5 V
SS
≤ 30 mA
1)
< 50 mA
2)
≤ 100 mA
≤ 500 μs
3)
1000 Hz
4)
see table
x4, xH, x5, xI: IP66, IP67, IP69
x9, xB: IP65
III
A, B, C, D
7)
–40 °C ... +60 °C
42
1
29,9
35,5
2
6
6,5
3
15
27,8
5
6
Figure 12: Dimensional drawing 2, male
connector
TECHNICAL DATA
1:
6)
8)
42
4,1
20
29,9
52,9
17,5
2
3
M12
7,5
28
35,5
4
12
6
6,5
3
15
5
6
13

Publicidad

Tabla de contenido
loading

Tabla de contenido