installation
installation
Securing the mounting bracket
9.4.4
Fitting the power cable
Installing the power cable
»
Prepare the power cable.
»
Use the plastic cap as an installation aid.
9.4.5
Inserting the twin nipples
Sealing in and inserting twin nipples
9.4.6
Preparing the water connection
»
Secure the tee and cross-piece to the twin nipples with flat
packing.
»
Thoroughly flush the cold water supply line.
www.stiebel-eltron.com
Three-way shut-off valve
Never use the three-way shut-off valve to reduce the
flow rate; it is only designed to shut off a circuit.
Water connection
1
1
Tee
2
Cross-piece
9.4.7
Fitting the sieve
»
Fit the sieve provided in the cold water inlet of the appliance.
Sieve
The sieve must always be fitted for the function of the
appliance to be guaranteed. If an appliance is being
replaced during installation, ensure that a sieve is
available.
Fitting the sieve
9.4.8
Installing the DmB flow limiter
»
Position the flow limiter provided in the cold water inlet of the
appliance.
A second flow limiter is provided with the DHB-E 18/21/24 SLi.
Install the flow limiter with an output corresponding to that of
the appliance. The colour of the flow limiter is given in the table
"Specification".
Installing the flow limiter
9.4.9
Mounting the appliance
The cable grommet pointing towards the wall may hinder the
mounting of the appliance close to the wall. To prevent such
problems, it is advisable to briefly press the cable grommet
2
dhB-e ... sli electronic |