Broan beot K7388 Manual Del Usuario página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Non-ducted recirculation Configuration
1. Adjust the width of the flue mounting
bracket to equal the inside width of
decorative flue. Insert and tighten
mounting screws to hold bracket width.
2. Use mounting screws and drywall
anchors to secure flue mounting bracket
to the ceiling as shown.
3. Turn upper flue section upside down so
air vents are at the top. Slide upper flue
section into lower flue section.
4. Connect the non-ducted recirculation
plenum to the upper flue section with (4)
flat-head screws (supplied).
5. Install the reduction on the discharge
collar.
6. Measure the distance from the top of the
reduction to the ceiling. Cut a length of 5"
round metal duct 5" shorter than this
dimension.
7. Fit duct section over the non-ducted
recirculation plenum. For best fit, make
sure duct seam is toward the front.
8. Set duct/flue assembly on hood with top
tilted away from wall. Reach around flue
to engage bottom of duct with discharge
collar on hood. Tilt flue up against wall.
Duct seam can be cut to length if
necessary.
9. Extend the upper flue to the ceiling and
secure with the two mounting screws.
UPPER
(in upper flue section)
FLUE SECTION
NON-
DUCTED
R E C I R C U L A T I O N
PLENUM
LOWER
FLUE SECTION
DUCT
5" ROUND
SEAM
METAL DUCT
REDUCTION
DISCHARGE
COLLAR
AIR
UPPER
VENTS
BRACKET
!
MEASURE
=
FLUE MOUNTING
BRACKET
FASTEN FLUE TO
UPPER BRACKET
WITH MOUNTING SCREWS
- 8 -
MOUNTING SCREWS
=
MOUNTING
SCREWS

Publicidad

Tabla de contenido
loading

Tabla de contenido