Name
Display
Description
ALM
Behavior during non-stable
ALM
distance measurement
RST
Reset to factory settings
rSt
DSP
Display settings
dSP
DLY
Setting the time functions for
dLY
the switching output.
NER
Distance assignment for 4 mA
nEr
or 0.04 V.
FAR
Distance assignment for
FAr
20 mA or 10 V.
Q_1
q_I
Distance assignment for
switching output Q1.
8020032.17U4 | SICK
Subject to change without notice
The factory setting of the analog output can be adjusted via the menu items ner and far:
The ner value defines the distance assignment for 4 mA / 0.04 V.
The far value defines the distance assignment for 20 mA / 10 V.
Analog output
24 mA
(>11 V)
20 mA
(10 V)
Sensing
range
4 mA
(0,04 V)
too close
<2 mA
(0,02 V)
If the switching output is to be set via the menu, adjust entry Q_1.
Value
Display
Initial
selection
value
CLP, HLD
X
cLP
hLd
NO, YES
X
no
YES
ON, OFF
X
on
oFF
OFF, OFD,
X
oFF
OND, SHT
oFd
ond
Sht
0 ... 300
0
0
0 ... 300
300
300
0 ... 300
300
300
too far,
no target
Distance
CONFIGURATION
Description
If the distance measurement
is not stable, the maximum
current/maximum voltage at
the analog output is issued.
If the distance measurement
is not stable, the most
recently valid current/voltage
value at the analog output is
maintained.
No reset.
Reset all values to factory set‐
tings with the exception of the
PNP/NPN selection.
Display shows display value in
cm.
Display switches off 30 sec‐
onds after an operating but‐
ton was last pressed.
No time function activated.
Switch-off delay, adjustable
from 0 ... 999 ms.
Switch-on delay, adjustable
from 0 ... 999 ms.
Single shot, adjustable from 0
... 999 ms.
Value range 0 ... 300
Value range 0 ... 300
Value range 0 ... 300
4
11