2.2
Dimensional drawing
3
Commissioning
3.1
Check the application conditions:
8020032.17U4 | SICK
Subject to change without notice
17.4
(0.69)
17
Ø 3.1
(0.67)
(0.12)
1
2
Receiver
1
Sender
2
Connection
3
RUN button
4
(+) button
5
Output display (orange)
6
Stability display (green/red), laser off display (off)
7
Output display (orange)
8
(-/Q1) button
9
Display
ß
(SET) button
à
Analog output:
Refer to
TableTechnical data
analog output.
Switching output:
Check the application conditions: Adjust the sensing range and distance to the object
or background and the remission capability of the object according to the correspond‐
ing diagram [H1, H2] (x = sensing range, y = minimum distance between the object and
background in mm (object remission / background remission)). Remission: 6% = black,
90% = white (referring to standard white as per DIN 5033).
The minimum distance (= y) for background suppression can be read from diagram
[H15] as follows:
Example: x = 1,000 mm, y = 20 mm. That is, the background is suppressed at a dis‐
tance of > 20 mm from the sensor.
WTT190L-A2xxx
1.9
Ø 3.1
32.8
(1.29)
(0.07)
(0.12)
7
(0.28)
6
(0.24)
3
2.8
(0.11)
28.3
(1.11)
4
5
6
7
8
à ß 9
and Diagram H3, H4 for the accuracy specifications of the
PRODUCT DESCRIPTION
WTT190L-A1xxx
WTT190L-A3xxx
1.9
32.8
(1.29)
(0.07)
7
(0.28)
3
6
(0.24)
2.8
(0.11)
2
5