Program switch used to select an operating mode, adjust the basic technical
service functions and alert about any malfunction when connected to a
BRAVO or ACTIVA+ operators. The operating modes available are:
+
-
Display with 2 digits and 7 segments: shows the selected operating
mode, in any of the following languages: English, Spanish, French,
German, Italian, Portuguese, Dutch and Catalan. In case a
malfunction is detected by the self-diagnostic system, a
numeric code will flash indicating the type of malfunction.
Buttons to access the Technical Service functions.
Buttons to select the desired operating mode.
4
Infrarred receiver (supplied as standard), to operate the door
5
from the optional remote control (code
manusa
AUT
AUT
Operating mode only available on
the Bravo operator equipped with
an automatic lock
).
EN
Display height
Operating frequency of the IR receiver
Maximum reach of the remote control
Power supply
Power consumption
Environment operating temperature
Dimensions
Wiring maximum length
The Optima Selector fits inside a standard plastic housing, and can be fixed
in three different ways:
- Flush mounted to any surface
- Mounted into the front cover
- Mounted into a wall
The connection to the operator is made using the supplied radio frequency
insulated cable with 4 x 0.25 mm wires. The radio frequency protection must
be earthed on either end. The cable length should not exceed 100 m.
TRANS.2
TRANS.1
13 14
15
16 17
18 19
M
01
10 mm.
38 Khz.
8 m.
12 vdc.
120 mA.
0ºC - 50ºC.
75 X 75 X 53 mm.
100 m.
REC.2
REC.1
20
21 22
23
24
EMSM03