SAFETY INFORMATION
Electrical Connection
•
A 15-Amp, 120-volt, 60 Hz circuit with
a properly grounded outlet is required.
Preferably, the fireplace will be on a dedicated
circuit as other appliances on the same circuit
may cause the circuit breaker to trip or the
fuse to blow when the heater is in operation.
The unit comes standard with 6-ft. three-wire
cord, exiting from the rear of the fireplace.
DO NOT exceed the current rating of the
current tap.
(CONT'D)
SAVE THESE INSTRUCTIONS
A
Grounding Pin
Grounding Instructions
•
This heater is for use on 120 volt. The cord
has a plug as shown below. See illustration
for grounding instruction. An adapter as
shown at C is available for connecting
three-blade grounding type plugs to two
slot receptacles. The green grounding
lug extending from the adapter must be
connected to a permanent ground such as
a properly grounded outlet box. The adapter
should not be used if a three-slot grounded
receptacle is available.
B
Metal
Screw
Cover of
Grounding
Box
4
C
Grounding Means
Adapter