SANUS VuePoint F215b Manual De Instrucciones página 8

Ocultar thumbs Ver también para F215b:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 16
2 Mount the Wall Plate
Wood stud
2-1 Locate studs
2-2 Mark the wall
[01]
2-3 Drill pilot holes
2-4 Tighten lag bolts
[01]
[11]
8
< 16 mm
(5/8 in.)
[##]
[10]
Verify the center of the stud(s) using an awl, a thin nail, or an edge to
edge stud fi nder.
CAUTION:
Avoid potential personal injuries and property
damage!
Any material covering the wall must not exceed 16 mm (5/8 in.).
Minimum wood stud size: common 51 x 102 mm (2 x 4 in. )
nominal 38 x 89 mm (1.5 x 3.5 in.)
Level the wall plate [01] and mark the hole locations.
CAUTION:
Avoid potential injuries or property damage! Pilot
holes MUST be drilled to a depth of 75 mm (3 in.), using a 5.5 mm
(7/32 in.) diameter drill bit.
CAUTION:
Avoid potential injuries or property damage!
Improper use could reduce the holding power of the lag bolt. To avoid
potential injuries or property damage
DO NOT over-tighten the lag bolts [11].
Tighten the lag bolts [11] only until the washers [10] are pulled
fi rmly against the wall plate [01].
13mm
5.5mm
(1/2 in.)
(7/32 in.)
75 mm
(3 in.)
6902-002025 <01>