Problem
Expected number of
test rundowns is not
achieved with one
charge of the battery.
10.2
WLAN data communication between controller and tool
Problem
No WLAN data commu-
nication between the
controller and tool.
IP address cannot be
pinged.
Occasional interrup-
tions in WLAN data
communication.
14
Possible causes
Remedy
 Use fully charged battery.
Battery is not fully
charged.
The warning threshold
On the controller screen Tool Setup > Tool Set-
for undervoltage is not
tings > Others > Battery.
set to minimum value.
 Reduce the Undervoltage (V).
High torque is needed
If a high torque is needed for a longer period of
during a fastening
time, e.g. for several turns, the number of run-
sequence, e.g. for
downs that can be achieved with one battery
coated fasteners.
charge will be significantly reduced.
Battery is at end of life.
 Use new battery.
Possible cause
Remedy for mPro400GCD (SW S168813)
The IP address of the
1.
tool is not correctly
entered in the
controller.
2.
IP address of tool – see Tool in submenu Wireless
Settings.
Tool not yet parameter-
 Use LiveWire Utilities Configuration Software
ized with the correct
WLAN settings.
WLAN settings are dif-
 Reconfigure the tool (network name, encryp-
ferent for tool and
access point.
 Add the MAC address for the tool to the list of
A filter for MAC
addresses is activated
at the Access Point.
MAC adress of tool – see
 Configure the firewall such that the required
Port 4001 is disabled
by a firewall.
The wireless channel at
 Change the wireless channel setting at the
the access point is out-
side the range sup-
ported by the tool.
Tool is already
 Check whether another controller already has
assigned to another
controller.
 Check the physical connection (RSSI values).
IP Address already
exists in network. In this
 Check the assigned IP address.
case, the tool will not
build up a connection.
Distance between the
1.
access point and the
tool is too great.
2.
The tool is already
1.
assigned to another
controller.
2.
Excessive data traffic
Reduce data traffic on WLAN Network.
on WLAN Network.
1.
2.
P2543BA | 2021-01
On the controller screen Tool Setup, check
whether the IP address of the tool has been
entered in the field Type.
Otherwise, mark the line and <Edit>.
to setup tool.
tion, network key).
approved addresses at the Access Point.
On the tool in the Wireless Settings submenu.
IP/MAC addresses can use port 4001.
access point to the right wireless channel with
respect to country code. See Quick Installa-
tion Guide – CTBP & CTBA Data Transmis-
sion P2545K.
a connection to this tool. In other words,
another controller is using the same IP
address.
On the tool use WLAN icon to check signal
strength at the tool.
If necessary, reduce the distance between the
access point and the tool.
Check whether the tool (IP address) is also
assigned to another controller.
If yes, delete the assignment in the other
controller.
A tool can only be assigned to one controller.
On the controller screen Basic, increase the
Trigger Torque.
On the controller screen disable the torque
graph data transmission:
Advanced > Controller > General > Trace
Recording