Programming

Automatic Cool-Down

NOTE: Can be disabled.
The automatic cool-down feature prevents the drain
from opening until the temperature of the water in the
sump falls below 140
F (60
This feature becomes active during a drain step, if the
step is programmed for "drAI" when the temperature
is above the threshold temperature. During the
cool-down, the COLD fill valve is energized, the drain
remains closed and the machine continues to agitate as
it did prior to the cool-down. When the temperature
falls below 140
F (60
C), the COLD fill valve turns
off and the drain step proceeds as normal.

Enabling/Disabling Cool-Down

NOTE: Factory default is disabled.
To enable or disable the cool-down feature, first enter
Program Mode, refer to page 7, then proceed as
follows:
1. After entering Program Mode display shows
temperature. Press Stop (*) key.
2. Display shows "
CEL". Press Start (#) key.
3. Display shows "HEAt". Press Start (#) key.
4. Display shows "CooL" if cool-down is enabled
or "noCL" if disabled. To change this, press Up
or Down (arrow) key.
5. Press Start (#) key to save and return to Program
Mode.