Instructions For Use With Wood; Use With Smokeless Fuel - FRANCO BELGE Belfort Instrucciones Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

"BELFORT" - ref. 134 04 11
1

3.2. Instructions for use with wood

3.2.1. Lighting
Figure 8
Slide the top air control (rep. B1) to the right. Open the
lower spin wheel (rep. C1).
Lay firelighters or rolled up newspapers on the grate
with a reasonable quantity, if necessary, of dry kindling
wood. Place 2 or 3 small logs on top.
Light the newspaper or firelighters using a long taper
and close the door.
When the fire is burning fiercely, add further logs of a
diameter up to 10 cm.
When the stove body is very hot, close the lower spin
wheel.
The burning rate can now be lowered by moving the
top air control to the left.
The airwash system works with the top airslide. When
the top airslide is full open the system works at its
strongest efficiency.
The more closed down the airslide is, the less effective
the airwash will be (when shut down completely, the
airwash system can not function).
3.2.2. Re-fuelling
Figure 8
- Slide the top air control (rep. B1) to the right. Open the
lower spin wheel (rep. C1).
- Open the glass door and add logs.
- Leave the lower spin wheel open for a few minutes to
allow the initial volatiles in the wood to burn.
- Close the lower spin wheel.

3.3. Use with smokeless fuel

3.3.1. Lighting
Figure 8
- Slide the top air control (rep. B1) to the right. Open the
lower spin wheel.
Technical manual "1174"
2
1
Figure 9 - Removing the fuel retainer
- Lay firelighters or rolled up newspapers on the grate
with a reasonable quantity, if necessary, of dry kindling
wood. Place a small quantity of solid fuel on top.
- Light the newspaper or firelighters using a long taper
and close the door.
- When the fire is burning fiercely, add further fuel.
- When the stove body is hot, close the top air control by
sliding to the left.
- The burning rate can now be adjusted by rotating the
lower spin wheel.
- The nominal output is achieved with secondary air
closed and primary air (rep. C, figure 8, page 8)
opened at 50 %.
- The airwash system works with the top airslide. When
the top airslide is full open the system works at its
strongest efficiency.
- The more closed down the airslide is, the less effective
the airwash will be (when shut down completely, the
airwash system can not function).
2
1
2
1 Oscillating grate
Figure 10 - Mounting the oscillating grate
and the ash tray
Instructions for user
2 Ash tray
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

134 04 11

Tabla de contenido