Electrical Connections - Jacuzzi Whirlpool Bath DESIGNER Serie Manual De Instalación Y Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Electrical Connections

A separate circuit, which must be protected by a Ground Fault
Circuit Interrupter (GFCI), is required. Install a duplex outlet to the
studwall underneath the bathtub, at least 4 inches above the floor.
The duplex outlet is not provided. Because these units are manufac-
tured with a safe, convenient Magic Touch whirlpool ON/OFF switch
on the bath itself, no remote switch or timer is necessary. If an op-
tional timer is desired, one is available from Jacuzzi Whirlpool Bath
for 115 VAC operation.
DANGER: RISK OF ELECTRIC SHOCK. Connect only to a circuit
protected by a Ground Fault Circuit Interrupter.
CAUTION: Operating the motor/pump without enough water in
the bath can cause leaking and permanent damage to the pump.
Before power is applied to the installation, make sure the switch
is in the OFF position to avoid pump damage.
LAMP JUNCTION BOX
LAMP J-BOX
TO MOTOR
115 VAC 20 AMP
CIRCUIT GFCI
CIRCUIT
LIGHT CONNECTION DIAGRAM
SWITCH IN MOTOR
LINE
115 VAC 20 AMP
LINE
CIRCUIT
GND
TO LIGHT
TRANSFORMER
JUNCTION BOX &
DUPLEX OUTLET
(NOT PROVIDED)
TO LAMP
TO LAMP
GREEN SCREW
ON J-BOX
BLK
TO DUPLEX
WHT
OUTLET BOX
GRN
11
ELECTRICAL CONNECTION
(FOR SIDE/END DRAIN BATHS)
ELECTRICAL CONNECTION
ELECTRICAL CONNECTION FOR LAMP
TO LAMP
JUNCTION BOX
3 PRONG
PLUG
DUPLEX
RECEPT.*
4" MIN.
FLOOR
*(NOT PROVIDED)
(FOR CORNER BATHS)
3 PRONG
PLUG
DUPLEX
RECEPT.*
4" MIN
FLOOR
*(NOT PROVIDED)
3 PRONG
PLUG
DUPLEX
RECEPT.*
4" MIN.
FLOOR
*(NOT PROVIDED)

Publicidad

Tabla de contenido
loading

Tabla de contenido