Handle
Bonnet
Indexer
Splines
6. Optional Temperature Limiting Adjustment
NOTE: The handle style shown may differ from the handle
supplied. The adjustment procedures still apply.
NOTE: The water temperature does not need to be adjusted if the
water temperature is below 105°F (41°C).
NOTE: Before adjusting the water temperature, ensure the handle is
turned all the way to the left. This is the maximum hot position.
Remove the plug button, setscrew, handle, and bonnet.
Reposition the indexer to stop the valve stem at the desired
maximum temperature.
Allow the water to flow through the spout and rotate the valve
stem to the full hot position to confirm the temperature setting.
Repeat the above procedures until the desired temperature is
reached.
Reinstall the bonnet and handle onto the faucet body. Secure the
handle with the setscrew.
Reinstall the plug button.
1059390-2-A
Setscrew
Plug
Button
Valve Stem
8
Kohler Co.