INSTRUCTIONS
MEASURING DC / AC
1.- Connect the red testing point to the jack signaled "VΩmA"
and the black testing point to the jack signaled "COM".
2.- Set the dial to the V - - - / V~ setting
When the value to be measured is unknown, set the dial to
the maximum setting. Reduce level by level until reaching the
desired one.
3.- Connect the testing points to the equipment to be measured.
4.- Turn the equipment to be measured on, the voltage will
appear on the LCD display. The polarity will also appear.
If you want to hold the value, press the hold button
V - - -
V~
ENGLISH-06