Putting Into Operation; Setting Up The Torch - Abicor Binzel B Serie Instructivo De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Welding torch B

4 Putting into operation

4.1 Setting up the torch

1
10
9
Type B 15
1
Gas diffuser
2
Contact tip
3
Tip adaptor
4
Setting up the torch
Fig. 1
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance,
servicing, assembly, disassembly and repair work:
• Switch off the power source.
• Close the gas supply.
• Close the compressed air supply.
• Disconnect the mains plug.
CAUTION
Risk of injury
Puncture or cut-in wounds may be caused by the wire electrode.
• Wear protective gloves and never reach into the danger zone.
Set up the torch neck according to the following figure:
2
3
8
Gas diffuser
5
Torch neck
6
Type B 501D
7
4 Putting into operation
4
5
7
Type B 36
8
Gas nozzle
9
10 Type B 25
6
EN - 5

Publicidad

Tabla de contenido
loading