3. How to Install the Indoor Unit
3-1. Remove the Rear Panel from the Unit
(1) Remove and discard the set screw on the rear
panel. (Fig. 6)
L L
(2) At the 2
marks on the frame cover, disengage the
stationary tabs from the frame by pulling in the direc-
¬
tion indicated by
. (Fig. 7a)
(3) Remove the rear panel.
(4) Remove the tape that is applied to the frame at
2 locations. (Fig. 7b)
NOTE
Tubing can be extended in 5 or 6 directions as shown
in Fig. 8a or 8b. Select the direction you need provid-
ing the shortest run to the outside unit.
G
When left tubing is to be done, switch the drain
hose and drain cap. (For details, refer to "Switching
drain hose and drain cap" on page 15.)
3-2. Make a Hole
(1) Place the rear panel from the indoor unit on the
wall at the location selected. Make sure the panel
is horizontal, using a carpenter's level or tape mea-
sure to measure down from the ceiling. Wait until
after cutting the hole before attaching the rear
panel to the wall.
(2) Determine which side of the unit you should make
the hole for tubing and wiring. (Fig. 9a or 9b)
NOTE
In the case of left-rear tubing, use the measurement
points from the edge of the rear panel for precise
placement of the hose outlet. (Fig. 9a or 9b)
(3) Before making the hole, check carefully that no
studs or pipes are directly run behind the spot to
be cut.
Also avoid areas where elec-
CAUTION
trical wiring or conduits are
located.
The above precautions are also applicable if tub-
ing goes through the wall in any other location.
(CS-ME18NKE, CS-ME24NKE)
60 mm
Fig. 9b
Set screw only for transportation
Rear panel
(CS-ME18NKE, CS-ME24NKE)
Left
tubing
Left-rear
tubing
(CS-ME7NKE, CS-ME9NKE, CS-ME12NKE)
Left
Left-rear
tubing
tubing
Left-downward
tubing
(CS-ME7NKE, CS-ME9NKE, CS-ME12NKE)
70 mm
7
Fig. 6
marks
Fig. 7a
Tape
Fig. 7b
Right-rear
tubing
(recommended)
Right tubing
Downward tubing
Fig. 8a
Right-rear
tubing
(recommended)
Right
tubing
Right-downward
tubing
Fig. 8b
Fig. 9a