- Pull the inlet pipe subjection (A) to the left and extract the
connection racor (B) from the inlet pipe (C).
- To remove the pump body press its subjection placed on its
left and keeping it pressed turn the pump anticlockwise until
unblock it. Extract the pump then, pulling it.
-unblock the inlet pipe subjection (A) and remove the inlet
pipe (C) by pulling it downwards.
- Remove the joint (C1) and the non-return valve (D) from the
inlet pipe (C)
17
- Extract the air flow regulator (E) and the air inlet valve (F)
from the pump tube.

7.1.5 Cleaning and sanitizing of components

To clean and sanitize the dismantled parts proceed as follows:
- Wash all disassembled components including the product
tank with drinkable water.
- Fill a bucket with disinfectant solution and introduce all of the
previously disassembled components.
- Let the solution work for 10/15 min.
- Rinse the elements thoroughly using drinking water.
- Place the components on a dry tray and let them drip dry.