Low level alarm
• mounted through the tank wall at the detection level
Standard configuration with extensions: top mounting
• Designed for top mounting, for high or low level alarm. Mount the probe vertically so that
it reaches into the process at the desired detection level.
Process Cautions
• The maximum allowable torque on a horizontally installed rod is 30 Nm.
• Keep unit out of path of falling material, or protect probe from falling material.
• Avoid areas where material build up occurs.
• Take into account material surface configuration when installing unit.
• Ensure tensile load does not exceed probe or vessel ratings

Mounting Instructions

Pointek CLS500 is available in three thread types: NPT, or R (BSPT), or G (BSPP). Make sure the
mounting connection threads are of the same type, then simply screw the device into the
process connection, and hand tighten.
Page EN-4
Pointek CLS500 – QUICK START MANUAL
CAUTION: Consider
material surface
configuration when
installing unit