Technical data
Nominal voltage
Mains frequency
Power consumption
Protection class
Protection degree
Cable length
Maximum welding current
Welding cycle for electrofusion couplings
(approx.)
Welding cycle for electrofusion tapes (approx.)
Welding cycle for electrofusion couplings with
integrated thermal fuse (approx.)
Minimum load resistance
Maximum load resistance
Fuse
Temperature range during operation
B1158-002 © 07-2016
966.473.00.0 (02)
100–240 V
50–60 Hz
1085–1810 W
I
IP55
4 m
5 A
80 s
80 s
7 min
5 Ω
68 Ω
12.5 A
-10 – +50°C
33
EN