9.23. Delete data
This menu item allows you to delete the following data:
1: -----
No deletion
2: Forces
Deletion of memorized forces
3: Distances +
Deletion of memorized end of travel positions and
Forces
forces
4: Configurations Deletion of all memorized configurations
9.24. Cycle counter
This menu item is a pure display menu, here you can read the number of
runs made so far. This value cannot be deleted or reset.
9.25. Version
This menu item is a pure display menu, here you can see which software
version is programmed in the control unit.
9.26. Motor parameter
This menu item is a display menu for the motor parameter.
9.27. Emergency function
In this menu item you can activate or deactivate the emergency function
(see section 7.5.: Button inputs A-D). After a RESET of the control, the
emergency function is inactive.
9.28. Restart
In this menu item you can activate or deactivate the restart.
If an active command is detected at inputs A-D after the voltage has been
switched on, the controls start the motor to assume the desired status /
end position. If an additional safety input is detected as active, the start to
the end position is not carried out.
Input A
Input B
Input C
After a RESET of the control, the restart is inactive.
With automatic closing – Starts opening the
gate and keeps the gate open
Starts opening in the mode "Open without
stop".
Starts closing in the mode "Close without
stop".
31