PROBLEM
Burner starts but does
not ignite, Flame Safety
Control Button lights
up
Flame goes out
or burns unsteadily
Burner does not switch
off
Burner switches off too
early
Black or gray/white
smoke from flue
Black/white exhaust
Black smoke/exhaust
coming from unit
Grey or white exhaust/
smoke coming from
unit
For the location of an authorized service center for your Dragon K85 Mobile Furnace, contact your
local distributor or the Dri-Eaz Service Department at 888-667-3235.
141 Kinderkamack Rd. Park Ridge, NJ 07656 Tel: 201-782-1782 Fax.. 201-782-1783 Web • www.amgaircorn Email: info@amgaircom
See
CAUSE
Above
AST
No ignition spark
Burner nozzle dogged
AST
Fuel intake filter is dirty
FS
Fuel pump screen is
FS
dirty or damaged
Burner nozzle filter is
AST
dirty
Fuel line leaks and lets
AST
in air
Bumer nozzle is
AST
clogged
Combustion air mixture
AST
adjusted improperly
Thermostat placed
FS
improperly
Thermostat defective
AST
Thermostat placed
FS
improperly
Improper air to fuel ratio
AST
Air intake vents are
AST
dirty or obstructed
Bad fuel air to fuel mix
ratio, and/or improper
AST
IF
fuel pressure setting.
.
a
Water in the fuel
%rd
en thy
emi,
too much air
Mt
g
fuel/air mixture
,
Air Marketing Group LW
SOLUTION
Call authorized service center.
Call authorized service center.
Replace the fuer intake filter
Clean or replace fuel pump screen
Call authorized service center
Call authorized service center
Call authorized service center
Call authorized service center.
Move thermostat so that it is not subject to cold air flow from
doorways windows. etc
Call authorized service center.
Move thermostat so that it is not subject to warm air flow or
heat radiation from the sun. machines hot water pipes. etc.
Call authorized service center or HVAC specialist.
Avoid setting up unit where the intake could be blocked or
restricted
e tall grass deep snow etc Blocking the air
i
intake will cause the unit to burn inefficiently resulting in
sooty exhaust and potential damage to the unit and the
structure being heated. Call authorized service center
FiVAC specialist.
Black smoke is an indication that the burner is receiving
more fuel than it needs to operate efficiently. Call authorized
HVAC specialist.
service center or
if
water
present in the fuel the fuel tank will need to be
is
drained arid
fuel filter will need to be replaced prior to
the
to operate the
attempting
unit. If the fuel does not contain
I
the fuel
ratio
:water, hen
to
air
grey/ white discharge Cat authorized service center or
FIVAC specialist
Of
is the most likely cause of the