Programming the Timers
The RC2 receiver features two independent timers (Timer1 and Timer2) for
automatic relay deactivation after a set time delay.
The deactivation time can be brought forward, compared to the timer setting,
by maintaining the "timer" command active for more than 3 seconds or by
giving an "Off" command.
The factory or default settings for the two timers are 1 minute (Timer1) and 10
minutes (Timer2) respectively.
The time settings can be programmed separately for each of the two timers,
from a minimum of 1 second to a maximum of 9 hours. Once the timer has
been programmed, every command associated with it will activate the relay
for the set time interval.
In order to program the timers you need to have a transmitter memorized for
timer control, then follow the steps in the table [G].
Table [G]
Programming the Timers
1
Press and hold down the transmitter
key associated with control of the timer
you wish to program. The relay will be
activated (On)
2
Hold the key down, after approx.
3 seconds the relay will be deactivated
(Off)
3
Hold down the same key for approx. 10
seconds, until the relay is activated again
(On). The time measuring stage starts at
this point. Release the key
12 – English
Example
"Relay ON"
3s "Relay OFF"
10s "Relay ON"