OPERATING INSTRUCTIONS
Important information
Target group
Qualified craftsmen
Specialist personnel trained by Techem
Intended use
The Ultrasonic heat meter ultra S3 is an energy meter for universal application in heat
and cold measuring systems.
Device properties
The computer unit is available in the following versions:
calculator heating for heat metering
calculator cooling for cold metering
calculator with cooling tariff for combined heat and cold metering
solar calculator as a special version for solar systems (there is no calibration for this
version)
1
Temperature sensor
Sensor identification
Safety and hazard information
The regulations for the use of energy meters must be observed.
Only clean the outside of the meter using a soft, slightly moistened cloth.
Power supply
Battery
A 3.6 V DC lithium battery is installed in the standard version.
Cannot be replaced.
!
Used batteries must be disposed of at the proper collection points!
– There is the danger of explosion if the wrong type of battery is used.
Power supply unit
A power supply unit can be retrofitted by a specialist electrician for use of the meter in
control systems at all times.
Power supplies are available with 24 V AC or 230 V AV.
Not suitable for consumption acquisition to create a legally binding cost allocation because
the measurement functions are inoperative during a power failure.
Equipment configuration / technical data
Standard measurement interval 16 seconds, optional 4 seconds
Optional fast measurement interval 4 seconds (e.g. for measuring hot water energy and
for local district heating stations)
The measuring accuracy meets the requirements of EN 1434
Energy-saving mode (display off)
Individual remote reading with optional Plug & Play modules (M-bus, pulse)
1
2
TH (heating)
R (red)
3
TC (cooling)
B (blue)
GB