Receiver - Wall-Mounted Appliance Module
To erase
This procedure consists of erasing all addresses you may entered
over time which are not valid to control your Home Automation
system.
1.Take off the paddle from the receiver.
2.Press and keep pressed the key PROG till LED lights up green
(after 3 seconds).
3.Release key PROG. both green and red LEDS blinks quickly on, to
turn of after after several seconds (LED to blink orange). Time to
rease depends on the number of entered valid addresses.
4.All addresses are now erased, receiver goes back as well in X10
standard comunication protocol.
5. Put on again the paddle (make sure
bottom right side).
Operating the RMA receiver
Gently press the upper key (ON) to turn on the appliance/light.
Gently press the lower key (OFF) to turn of the appliance/light.
Make use of a remote control, RF wall switch, programmer to check remote control
of the appliance, light, etc.
Troubleshooting:
www.ebodeelectronics.eu
RMA cannot be controlled anymore from either an RF or PLC remote/
programmer ?
- Check and/or change the battery of your remote.
- Go for an overall RESET of the receiver as it may have lost the address due to
too many manipulations (starts from point 5), then re-initialize transmitter and
receiver both together (starts from point 3).
- Red or Green LED blinks randomly even if no remote control is performed :
RF or PLC interference may occur (ie Fluo lamps, Reversible A/C, PC monitor)
please add either a filter FD10 in the main control panel or a plug in module FM10
to filter the product in cause.
July 2009