Descargar Imprimir esta página

Desoutter ELS7-360-A4S Manual De Instrucciones página 16

Ocultar thumbs Ver también para ELS7-360-A4S:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 24
6159931420
Issue no : 10
Series : C
REVERSE ACTIVATION
K
See page 7.
TWO REVERSE MODES
L
See page 8.
Legend
L1 Mode 1: one touch reverse (default)
L2 Mode 2: Permanent reverse
BATTERY CHECK
M
See page 8.
LOW BATTERY STATUS AFTER EACH
TIGHTENING
N
See page 8.
SPEED SETTING MODULE - V2
O
See page 9.
ANGLE HEAD ADJUSTMENT
P
See page 11.
ERROR CODES
Error
4 red flashing lights Clutch sensor error. The
5 red flashing lights Exceeding of the maximum
16 / 128
Description
tool does not start or stops
instantaneously.
temperature (70°C). The
tool does not start or stops
instantaneously.
NETWORK CONNECTION
(FOR ELC TOOLS)
Q
See page 12.
SPECIFIC COMMUNICATION LED
(FOR ELC TOOLS)
R
See page 13.
No communication to network.
See "Q" page 12.
Tool locked.
Batch complete.
Preventive maintenance.
PREVENTIVE MAINTENANCE
It is recommended to lubricate (use Molykote
BR2+ grease) the clutch and the gearbox every:
- 500,000 cycles for 18V tools.
- 250,000 cycles for 36V tools.
ELC tools only
● Perform the maintenance of the
clutch every 500,000 cycles.
● Contact your local Desoutter
representative for the maintenance
procedure.
Validation / Action
The signal given by the clutch sensor is out of
tolerances. Check the sensor and the magnets
joined to the sensor. Check the flex is correctly
connected to the electronic board. If the fault still
appears, contact our customer service.
The temperature measured with the electronic
board is higher than 70°C. Wait for the tool
cool down. The tool can tighten again when
the temperature is lower than approximately
70°C. Decrease the tool rate. If the temperature
is lower than 70°C and the fault still appears,
contact our customer service.
04/2014

Publicidad

loading