aquatermic XK49 Manual Del Usuario página 30

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Heating setting
temperature
P38
under auto
mode
Set priority
P43
operation
Clear Filter
Clean
P46
accumulated
time
Opening angle
P49
of indoor unit
air-return plate*
Air outlet
temperature
P50
setting for Fresh
Air Indoor Unit
in cooling*
Air outlet
temperature
P51
setting for Fresh
Air Indoor Unit
in heating*
Union setting of
P54
Fresh Air Indoor
Unit*
16° C~29° C(61°
20° C
F~84° F)
(68° F)
00: normal
operation
01: priority
operation
00: do not clear
01: clear
01: angle
1(25° )
02: angle
2(30° )
03: angle
3(35° )
18° C
16° C~30° C
16° C~30° C
22° C
00: without
union control
01: with union
control
27
Wired Controller XK49
When power supply is insufficient, the
indoor units which are set to priority
00
operation can operate, while other
indoor units are forced to be turned
off.
Note: The filter-clean reminder
00
function is not available for this wired
controller.
Only applicable to units with air-return
01
plate
Only applicable to Fresh Air Indoor
Unit.
Only applicable to Fresh Air Indoor
Unit.
After union function is set, Fresh Air
Indoor Unit will be turned on/off
following the on/off status of common
indoor unit. Besides, Fresh Air Indoor
00
Unit can also be turned on/off
manually.
Note: only applicable to Fresh Air
Indoor Unit.