Establishing The Electrical Connection En - Abicor Binzel BRS-CC Instructivo De Servicio

Unidad de mantenimiento
Ocultar thumbs Ver también para BRS-CC:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5 Putting into operation
7 Fasten the adjusted motor position by means of the screws (3).
8 Move the torch out the clamping device (1) and remove the distance sleeve (7) from the
milling cutter (6).
5.8 Establishing the electrical connection
Four robot outputs 24 V DC and one robot input 24 V DC are required for controlling the valve.
NOTE
The cleaning station must be and remain without pressure and tension during setup!
• The gas nozzle diameter must match the one of the prism.
• The distance sleeve must match the nominal diameter of the gas nozzle.
• The milling cutter must be adapted exactly to the torch type.
Fig. 10
EN - 13
lmax < 200 mA
lmax < 200 mA
lmax < 200 mA
lmax < 200 mA
lmax < 200 mA
24 V DC
GND
Electrical connection
Injection
Lift
Cutter
Valves: clamp, motor
Signals: Lift down
BRS-CC