Setting functions 1-3, 5-10:
• Long press SET (> 5s) to enter programming mode.
• The green LED will fl ash by function (function 1 - 1x, 2 - 2x ...).
• Short (<1s) by pressing the SET button to move upwards in the function selection, press
(> 2 / <5s) longer to go down the function selections.
• Pressing the button (> 5s) long saves the set function and restarts the device.
Restart
• Open the cover. Power interruption (remove the battery from the device).
• Press SET> 1min.
• Connect power (insert battery). Close the cover.
Device states
Unit initialization
Start
Search for BTS * 2)
SIM ERR *2)
ERR *2)
Successful network connection * 2)
Measurement
Tamper
Magnet
SET button short press (> 2s)
SET button longer press (> 2s / <5s)
Measurement signaling * 1)
Communication
Communication
Other known states
Does not respond to the SET button
The unit is still in reset
The unit does not respond even after
removal insert the battery
When the tamper is pressed, the LED is turned off !
Note:
R... LED red
G... LED green
2.
6.
9.
Indication
3 x R + G blinks
2 x fl ashes R (2xR _ 2xR _ ...)
5 x fl ashes R (repeatedly)
1 x fl ashes R
without indication
3 x fl ashes G
1 x fl ashes G
2 x fl ashes G
1 x fl ashes G
1 x fl ashes R
any LED lights
still indicates start
without indication
Replacing batteries
3.
1
7.
1. Using a fl at-blade screwdriver gradually slide it into one and then the other groove in
the lid and swing open the cover.
2. Remove the discharged battery and insert a new battery into the holder. Beware of
polarity. Both LEDs will fl ash 3 times (see device status indication).
3. Replace and snap the front cover.
Notice:
10.
Only use batteries designed for this product correctly inserted in the device! Immediately replace
weak batteries with new ones. Do not use new and used batteries together. If necessary, clean the
battery and contacts prior to using. Avoid the shorting of batteries! Do not dismantle batteries, do
not charge them and protect them from extreme heating - danger of leakage! Upon contact with acid,
immediately rinse the aff ected area with a stream of water and seek medical attention. Keep batteries
out of the reach of children. Batteries must be recycled or returned to an appropriate location (e.g.
collection container) in accordance with local legal provisions.
AirIM-100S
power supply (external or battery), reset unit
x
error MAC / error MODULU / error SIM
setting mode (signaling of measurement / pulses)
impulse LS / MS / WS / S0, temperature measurement, ...
it is necessary to disconnect the power supply (external or battery), after 60 seconds after the LED goes out, insert the battery
a discharged battery or a damaged product
* 1) Indicates only when you press SET> 2 s (setting mode)
* 2) Planned
3 / 4
2
AirIM-100L
Search availability BTS
SIM Error - cannot be loaded (SIM
card insertion and rotation check) / or
start unit ok
opening the cover
non contact / contact magnet
test, cancel, „long press"
sending / receiving data
the battery may be discharged
3
Click!
AirIM-100NB