Install An Electrical Outlet - Kohler K-4709 Guia De Instalacion

Ocultar thumbs Ver también para K-4709:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

GFCI-Protected
Receptacle
Supply Stop

1. Install an Electrical Outlet

WARNING: Risk of electric shock, fire, or personal injury.
This product must be grounded. Connect only to a dedicated
120 VAC, 60 Hz circuit protected by a minimum 15 Amp
Ground-Fault Circuit-Interrupter (GFCI) or Residual Current
Device (RCD).
Do not use an extension cord with the product.
NOTE: Follow local codes when determining the electrical outlet
location.
Route the electrical and install to a 120 V GFCI- or RCD-protected
receptacle. The electrical outlet should be located within 32" (813
mm) of the toilet to accommodate the length of the power cord.
2. Preparation
If applicable, remove the existing toilet seat.
Turn off the water supply to the toilet.
Flush the toilet to relieve any pressure from the water supply
hoses.
Disconnect the water supply hose from the toilet fill valve.
Kohler Co.
5
1054180-2-F

Publicidad

Tabla de contenido
loading

Tabla de contenido