Connecting A Water Separator; Lubrication; Insertion Tool - Chicago Pneumatic CP 0112 Instrucciones De Seguridad Y De Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 58
Safety and operating instructions
Connecting a water
separator
The length of the air hose between the compressor
and the water separator must be such that the water
vapour is cooled and condenses in the hose before
reaching the water separator.
If the ambient temperature is below 32 °F (0 °C) the
hose must be short enough to prevent the water
from freezing before reaching the water separator.

Lubrication

Lubrication
The lubricant is important for the machine s function
and has a great impact on the service life. In order
to supply the correct volume of oil, an oiler should
be connected to the air hose. The use of a Chicago
Pneumatic air line oiler is recommended. To
guarantee good lubrication, the length of the air
hose between the oiler and the pneumatic tool
should not exceed 10 feet (3 m).
Too much lubrication can cause starting problems,
low power or uneven performance.
Use a synthetic lubricant such as CP Airolene Plus
Tool Oil or mineral oil with the properties
recommended in the table below.
Temperature
Lubricant
range °F (°C)
CP Airolene Plus
-4 to +120
Tool Oil
(-20 to +50)
Air tool oil
-4 to +60
(-20 to +15)
Air tool oil
+60 to +120
(+15 to +50)
It is recommended that the oil contains a
rust-inhibitor.
Checking the level and filling lubricant
Oil levels should be checked daily.
Wipe clean around the oil plug and remove it.
Check that the threads are not damaged or worn
out.
Any part with damaged or worn out threads must
be replaced.
Fill lubricant in the oil chamber (A).
14
CP 0112, CP 0112 S and CP 0112 EX

Insertion tool

The tip of the working tool can become hot and
sharp when used. Touching it can lead to burns and
cuts.
NOTICE
it can result in brittleness and early failure.
Selecting the right insertion tool
Selecting the right insertion tool is a precondition
for proper machine function. It is important to select
insertion tools of high quality to avoid unnecessary
machine damage.
The machine can be destroyed if you use an incorrect
Viscosity
insertion tool.
-
Recommended insertion tools are listed in the
machine's spare parts list.
100-150 SUS
(ISO VG 22-32)
Narrow chisel
225-350 SUS
(ISO VG 46-68)
Moil point
Wide bladed chisel
CP 0112, CP 0112 S, CP 0112 EX
Tighten the plug firmly and wipe off any excessive
oil.
CAUTION
Hot working tool
Never touch a hot or sharp working tool.
Wait until the working tool has cooled down
before carrying out maintenance work.
Never cool a hot insertion tool in water,
The narrow chisel is used for
demolition and cutting work in
concrete and other types of
hard materials.
The moil point is only used for
making holes in concrete and
other types of hard materials.
The wide bladed chisel is used
in soft materials, such as
asphalt and frozen ground.
9800 0798 90e | Original instructions
A

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Cp 0112 sCp 0112 ex

Tabla de contenido