BATTERY INFORMATION
Retain the original product literature for future reference.
Duraflow uses high energy density li-ion battery. Both standard and extended
versions of the battery are available.
Charge the battery fully before use.
Typical estimated life of a Duraflow Lithium-ion battery is 2-3 years or 300 to 500
charge cycles, whichever occurs first. The battery must be replaced at the end of
this period.
If the battery becomes dirty, wipe the terminals with a clean dry cloth.
BATTERY DURATION INFORMATION
Battery life is dependent on the type of filter and headtop that you select. Use the
following two tables to determine the battery operating times that you can expect.
The following operating times are based on a fresh battery that is fully charged, and
is used in combination with new filters.
The following circumstances may negatively impact the operating times:
•
Extremes of age and battery cycle
•
The charge status
•
Clogged filters
•
High workrates
The following table outlines the different battery times for standard and extended
batteries when combined with different headtops and filters.
Battery Type
Standard
Standard
Extended
Extended
BATTERY STORAGE
When the battery is not in use, charge the battery until it is full, then store the
battery in a cool place. Ensure that the battery is charged biannually.
Store the battery within the temperature range of -10°C to 50°C. Optimum battery
storage is 20°C.
Keep the batteries and cells clean and dry.
After extended periods of storage, it may be necessary to charge and discharge the
battery several times to obtain maximum performance.
Caution: Storing a battery that has depleted can damage the battery.
Duraflow
Filter Type
Combination
Particulate
Combination
Particulate
6
MMDF
Min Battery Run Time
160 Lpm
4.5 hours
160 Lpm
8 hours
160 Lpm
9 hours
160 Lpm
16 hours