Checking the horizontal line side to side
1. Set the instrument up approximately 8' (2.5m) from a wall that is at least
16' (5m) long.
2. Project the laser cross 1' (30cm) from one corner (1). Mark point (2) along
the horizontal laser line 8' (2.5m) from the intersection of the laser cross.
3. Rotate the instrument so that the laser cross (3) is projected at the wall
15' (4.6m) away from the first laser cross point (1).
4. The deviation of the horizontal laser line from the point (2) marked
previously should not be further apart than 1/8" or 3 mm.
6
Warranty
The CL30 laser is guaranteed to be free of manufacturing defects for a peri-
od of 2 years (in North America, one year, with warranty to two years with
online or mail-in registration within 45 days of purchase). Any abnormal
usage or if the instrument has been subjected to shock will void this warran-
ty. Under no circumstances will the liability of the manufacturer exceed the
cost of repairing or replacing the instrument. Disassembling the instrument
by other than qualified and certified technicians will void this warranty.
Specifications are subject to change without notice.