Kohler K-72218 Guía De Instalación Y Cuidado página 17

Grifería electrónica de cocina
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting (cont.)
Faucet Troubleshooting Table
Symptoms
3.
Poor spray
pattern.
4.
Green power LED
is not lit.
5.
Water drip or
trickle when
faucet is not in
use.
Solenoid Troubleshooting Table
Symptoms
1.
Water leaking
from the solenoid
valve.
No audible "click"
2.
when solenoid is
activated.
Kohler Co.
Probable Causes
Recommended Action
E. Refer to the "Cleaning
E. One or more
screens are
the Screens" section.
clogged.
F.
Cracked
F.
Replace the solenoid
diaphragm.
valve assembly.
A. The spray
A. Rub your finger over
nozzles are
the nozzles with water
clogged.
running to dislodge
debris.
A. No power to
A. Check the power
the circuit
supply connections to
board.
the circuit board.
B. Power cord is
B. Plug the power cord
plugged into
into an unswitched 120
a switched
VAC outlet (test the
outlet.
outlet with a radio or
other device). Confirm
the circuit board LED
illuminates.
A. Manual
A. Turn the manual
override is
override clockwise until
partially
it stops; then turn it
engaged.
counterclockwise until
the water drip stops.
Probable Causes
Recommended Action
A. Hose
A. CAUTION: Risk of
connections
personal injury or
are not
product damage. Turn
secure.
off the main power and
water supply. Check all
connections. Make
adjustments as needed.
B. Internal leak.
B. Replace the solenoid
valve assembly.
A. Loose
A. Check solenoid wire
solenoid wire
connection to the circuit
connection.
board.
B. Solenoid
B. Replace the solenoid
valve is not
valve assembly.
functioning.