7.4. ENVIRONMENTAL PARAMETERS
Range of use
-10 to 40°C, during battery recharging
-10 to 55°C, during measurement
10 to 80% RH
Storage:
-40 to 70°C
10 to 90% RH
Altitude: < 2000 m
7.5. CONSTRUCTION SPECIFICATIONS
Overall dimensions of the unit (L x W x H): 270 x 250 x 180 mm
Weight: approx. 4.3 kg
7.6. COMPLIANCE WITH INTERNATIONAL STANDARDS
Electrical safety as per: EN61010-1, EN61557
Dual insulation
Pollution level: 2
Measurement category: III
Max. voltage relative to earth: 1000 V (2500 V in measurement category I)
7.6.1. ELECTROMAGNETIC COMPATIBILITY
Emissions and immunity in an industrial setting compliant with EN61326-1
7.6.2. MECHANICAL PROTECTION
IP 53 per EN60529
IK 04 per EN50102
7.7. VARIATIONS IN OPERATING RANGE
Infl uence
Range of infl uence
quantity
Battery voltage
Temperature
Humidity
10...80% HR
Frequency
AC voltage
superimposed on
(5): The terms DAR, PI, DD and the capacitance and leakage current measurements are included in the
quantity "M ".
Quantity
infl uenced
V
9...12 V
M
V
-10...+55°C
M
V
M (10 k à 40 G )
M (40 G à 10 T )
15...500 Hz
V
M
0...20%Un
76
Infl uence
(5)
Typical
< 1 pt
< 1 pt
0.15%/10°C
0.20%/10°C
0.2%
0.2%
0.3%
3%
0.1%/% Un
Maximum
2 pt
3 pt
0,3%/10°C +1 pt
1%/10°C + 2 pt
1% +2 pt
1% +5 pt
15% +5 pt
0.5% +1 pt
0.5%/% Un +5 pt