Star Progetti HELIOSA 55 Instrucciones De Uso página 14

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

7. WIRE GUARD
a) The wire guard should be used if protection is required (for example sports halls or places where games are played). In areas
where indoor football is played, it may be necessary to fit additional external guarding to cope with the force of impact.
b) The wire guard is simply clipped over the front of the reflector.
c) The wire guard must be installed when the heater is fixed under a height of 2,5 m from the floor level and this assembly must be
done during installation and by a qualified electrician.
d) The HELIOSA® 55 protective wire guard has been designed to prevent direct access to the heating elements and must not be
removed while the heater is being used.
e) The guard does not guarantee full protection for children or the disabled.
8.MAINTENANCE AND REPLACEMENT OF BULB
(TO BE PERFORMED BY QUALIFIED STAFF OR SPECIALIZED TECHNICIAN)
• THE GUARANTEE DOES NOT COVER REPLACEMENT OR REPAIR OF BULB.
• REPLACEMENT OF BULB IS TO BE PERFORMED ONLY BY PROFESSIONALLY QUALIFIED PERSONNNEL OR BY A SERVICING CENTRE.
• REMOVE DUST FROM THE REFLECTOR AND BULB PERIODICALLY WITH BRUSH OR COMPRESSED AIR FOR CONSTANT HELIOSA® HI
DESIGN 55 HEAT EFFICIENCY.
• THE REPLACEMENT BULB MUST BE THE SAME AS THE BULB SUPPLIED WITH THE DEVICE.
• REPLACEMENT WITH OTHER BULBS MAY DAMAGE THE DEVICE AND CAUSE IT TO BE UNSAFE. CONTACT STAR PROGETTI OR THE
RETAIL OUTLET AUTHORIZED TO SELL THE REPLACEMENT BULB, SPECIFYING THE MODEL AND CODE OF THE PURCHASED
HEATER.
• THE INJECTION POINT ON THE BULB (c) MUST ALWAYS FACE OUTWARD.
BEFORE PROCEEDING WITH BULB REPLACEMENT, OPERATORS MUST:
1. FULLY DISCONNECT THE DEVICE FROM POWER SUPPLY AND MAKE SURE THE BULB IS COLD
2. NOT TOUCH THE BULB WITH THEIR BARE HANDS.
14

Publicidad

Tabla de contenido
loading

Tabla de contenido