ABIMIG
GRIP W
7.1 Cable assembly
7.2 Cleaning the torch neck
1 Unscrew the cable assembly on the machine side and bring it into a
stretched position.
2 Unscrew nut and pull out liner or PA liner and replace it, if necessary.
3 Remove wear parts from the torch neck.
WARNING
Risk of injury
Serious injuries caused by parts swirling around.
• When cleaning the wire guide with compressed air, wear suitable
protective clothing, in particular safety goggles.
4 Clean wire conduit from both sides with compressed air.
5 Mount cleaned or replaced wear parts and liner or PA liner.
6 Connect cable assembly on the machine side to the wire feed unit.
NOTE
• Clean the gas nozzle interior regularly to remove weld spatter and spray
it with original ABICOR BINZEL anti-spatter agent.
• Check the wear parts for visible damage and replace defective parts.
7 Maintenance and cleaning
EN - 9