Connect the Power Cable
1.
Verify the 24VDC power supply being used is unplugged and not
receiving power.
2.
Attach the power cable's -24V wire to Pin 2 and the +24V wire to Pin
3 on the green power connector supplied with VisionView. Connect a
frame ground wire from Pin 1 to frame ground. Tighten the wire retention
screws.
3.
Insert the green connector into the Power Connector port and tighten the
connector screws.
Caution: Do not connect AC power directly to the VisionView Power
Connector.
4.
Restore power to the 24VDC power supply and turn it on if necessary.
5.
Slide the VisionView Power Switch (located directly above the Power
Connector port) to the ON position.