If you wish to totally cancel the memory, proceed as follows:
Table "A6"
Total cancellation of the memory (fig. 12)
Simultaneously press and hold down the ▲ up and ▼ down controls.
1.
2.
Wait approximately 3 seconds for the awning to move briefly up.
Release the button, for example ▼.
3.
4.
Push and release the button (released at pint 3) three times within 3 seconds from when
the awning performed the brief raising movement.
5.
Then release the other button.
Note: Cancellation can be made at any time; if cancellation has been correctly performed the motor will turn in both directions briefly inter-
rupting the operation.
5) Disposal
As for the installation, the disposal of the product at the end of its
effective life, must be performed by qualified personnel.
This product is made of various types of material, some of which can
be recycled while others must be disposed of. Enquire about the
recycling or disposal systems available for this product category in
compliance with regulations locally in force.
Warning: some parts of the product may contain polluting or haz-
ardous substances that, if incorrectly disposed of, could have a
damaging effect on the environment or on the health of individuals.
6) What to do if...
a brief troubleshooting guide!
Though an electrical phase is supplied with power, the
motor does not turn. Check to see if the overload protection has
triggered (in this case just wait for the motor to cool down); then
make sure that the motor is powered at the correct mains voltage,
measuring between the Common wire and the supplied electrical
phase; finally try powering the opposite electrical phase. If the motor
still does not turn, something might be seriously wrong with the elec-
tronic switch control unit or the motor windings.
The motor doesn't start when raising. If the awning is closed or
nearly closed the motor will not perform the raising manoeuvre, the
awning must be lowered for a short section and then raised again.
During the UP phase, before reaching the "0" position, the
motor stops and then makes 3 attempts to start up again.
This doesn't necessarily mean trouble: in case of overload during the
up phase the motor is switched off for 1 second and then makes 3
7) Technical characteristics of the NEOSTAR-ST; NEOSTAR-MT and NEOSTAR-LT tubular motors
Supply voltage and frequency:
Current and power:
Torque and Speed:
Motor diameter:
Precision (resolution) of the electronic limit switch:
Precision of the limit switch stop positions:
Mechanical resistance:
Nominal operation time:
Protection class:
Operating temperature:
Connection cable length:
Nice S.p.a. reserves the right to modify its products at any time without notice.
As indicated by the symbol in figure, this product
must not be disposed of in household waste.
Perform "separated collection" for disposal in
compliance with regulations locally in force, or
return the product to the manufacturer when
purchasing a replacement.
Heavy fines may be imposed by local laws for the illegal disposal of
this product.
attempts to complete the manoeuvre.
If this happens again for another three times in succession and the
motor blocks again on the following raising manoeuvre, the present
position of the awning then becomes the new "0" position.
During the down phase, before reaching the "1" position,
the motor stops. This does not necessarily mean trouble: in case
of overload during the down phase the motor is switched off.
During the down phase the motor makes only half a revolu-
tion, while in the up phase it appears to turn normally.
You must allow the up manoeuvre to be completed to enable the lim-
it switch system to realign its position to "0".
The motor performs a half turn both raising and lowering.
The memory needs to be cancelled (table A6) and all positions pro-
grammed again.
See the technical data on the label attached to each model
See the technical data on the label attached to each model
See the technical data on the label attached to each model
NEOSTAR-ST=35mm; NEOSTAR-MT=45mm; NEOSTAR-LT=58mm;
greater than 0.55° (depending on the NEOSTAR_T version)
Class 2 (±5%)
in accordance with EN 14202
Maximum 4 minutes
IP 44
-20 ÷ 55°C
3 m