English
Diagram Reference
Components and Beeps
1
Alarm Keypad
Indicator
Set
Product Information
Fault
COPYRIGHT ©2019 Hangzhou Hikvision Digital Technology
Network
Co., Ltd.
ALL RIGHTS RESERVED.
Armed/Disarmed
Any and all information, including, among others, wordings,
pictures, graphs are the properties of Hangzhou Hikvision
Alarm
Digital Technology Co., Ltd. or its subsidiaries (hereinafter
Key
referred to be "Hikvision"). This user manual (hereinafter
referred to be "the Manual") cannot be reproduced,
changed, translated, or distributed, partially or wholly, by
any means, without the prior written permission of
Beeps
Hikvision. Unless otherwise stipulated, Hikvision does not
One Beep
make any warranties, guarantees or representations,
express or implied, regarding to the Manual.
Two Beeps
About this Manual
Five Beeps
This Manual is applicable to Alarm Keypad.
Slowly Continuous Beeps
The Manual includes instructions for using and managing
the product. Pictures, charts, images and all other
Rapidly Continuous Beeps
information hereinafter are for description and explanation
only. The information contained in the Manual is subject to
Rapid Beeps
change, without notice, due to firmware updates or other
Three Long Beeps and Two Short Beeps
reasons. Please find the latest version in the company
Three Beeps
website (http://overseas.hikvision.com/en/).
Keypad Address Settings
2
Please use this user manual under the guidance of
Configure the address via DIP switch of the keypad before powering on the
professionals.
system. The address should be in the range of 0 to 31. The address of each
keypad should be unique.
Trademarks Acknowledgement and other
The binary value shown in the diagram is 00010, which means the decimal value
Hikvision's trademarks and logos are the properties of
is 2. So the address of the keypad is 2.
Hikvision in various jurisdictions. Other trademarks and
Keypad Wiring and Installation
3
logos mentioned below are the properties of their
a. Dimension
respective owners.
b. Wiring
Route the cables through the cable hole of the rear panel, and Connect the
This product and - if applicable - the supplied
cables to the corresponding terminals.
accessories too are marked with "CE" and comply
c. Install Keypad
therefore with the applicable harmonized European
1. Loosen the screw, and pry the gap of the edge with a straight screw
standards listed under the RE Directive 2014/53/EU,
driver to disassemble the keypad. Remove the rear panel.
the EMC Directive 2014/30/EU, the LVD Directive
2. Secure the mounting plate on the gang box/wall with supplied screws.
2014/35/EU, the RoHS Directive 2011/65/EU.
The Input voltage should meet both the SELV (Safety
3. Fasten the keypad body on the plate.
4. Tighten the screw on the button to fix the keypad on the mounting plate and
Extra Low Voltage) and the Limited Power Source
complete the installation.
according to the IEC60950-1 standard. Please refer
Keypad Operation Commands
4
to technical specifications for detailed information.
Function
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
Arming/Disarming
upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For
more information see: www.recyclethis.info
Bypass
Legal Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW,
Clearing alarm
THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE
AND FIRMWARE, IS PROVIDED "AS IS", WITH ALL FAULTS AND
Partition
ERRORS, AND HIKVISION MAKES NO WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING WITHOUT LIMITATION,
MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A
PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD
Keypad Settings
PARTY. IN NO EVENT WILL HIKVISION, ITS DIRECTORS,
OFFICERS, EMPLOYEES, OR AGENTS BE LIABLE TO YOU FOR
ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT
DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR
LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR
Testing
LOSS OF DATA OR
DOCUMENTATION, IN CONNECTION WITH THE USE OF THIS
Panic
Fire alarm
PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES.
Specification
REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE
Model
USE OF PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS.
Numeric key
HIKVISION SHALL NOT TAKE ANY RESPONSIBILITES FOR
Function key
ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER
Indicator
DAMAGES RESULTING FROM CYBER ATTACK, HACKER
Screen
ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY
Input
RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY
Output
Keyfob
TECHNICAL SUPPORT IF REQUIRED.
Tamper switch
SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK
RS-485 Interface
ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING
Port
THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE
Sound
Card reading
CONFORMS THE APPLICABLE LAW. HIKVISION SHALL NOT BE
Power supply
LIABLE IN THE EVENT THAT THIS PRODUCT IS USED WITH
Power consumption
ILLEGITIMATE PURPOSES.
Temperature
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL
Humidity
Dimension (L × W × H)
AND THE APPLICABLE LAW, THE LATER PREVAILS.
Weight
1
Solid Green: No Configuration
Flashing Green: In the Configuration Status
Solid Orange: System Fault
Off: No Fault
Solid Green: All Enabled Channels Connected Normally
Off: Part of or All Enabled Channels Connected Abnormally
Off: Disarmed
Solid Blue: Armed
Flashing Red: Alarm Occurred/Tamper Alarm
Off: No Alarm
Query
Project
Bypass
Scoll Up
One-Push
Scoll Down
Fire
Panic
to Arm
Pressing keys/command timed out or too long/Fault Prompt.
Valid command/Report uploaded.
Invalid command/Failed to upload the report in 60 s.
In the Entry/Exit delay status, the Delay zone armed,
or 2 min before auto arming/disarming starting.
In the Entry/Exit delay status, the Delay zone
triggered, or 1 min before auto arming/disarming
starting.
Zone alarm/keypad not registered.
Keypad tampered.
Keypad registered.
It is required to insert the screw for tamper alarm.
Description
Command
Normal (Away) arming/disarming
[Password] [#]
Stay arming
[Password] [*] [4] [#]
All Partition away arming
[Password][Project] [#]
All Partition away arming
[Password] [*] [4] [Project] [#]
[Password][Bypass][n] [n] [n] [#]
Bypass zone(n)
[Bypass][n][n][n][#]
nnn is the zone No.
Clearing under arming status
[Password] [*][1][#]
Enter partition settings page
[*][3][Partition No.][#]
Exiting partition settings page
[*][#]
Enabling/Disabling keypad tone
[*][5][1][#]
[*][5][2][n][n][n][#]
LCD backlight control
nnn is LCD backlight lightening time
Enabling/Disabling tamper-proof
[*][5][4][#]
LCD backlight disabling
[*][8][#]
Display English
[*][9][1] [1][#]
Display Chinese
[*][9][1] [0][#]
Walk testing
[Password][*][6][0][#]
Exiting walk testing
[Password][*][6][2][#]
Panic
[Emergency]
Fire alarm
[Fire alram]
DS-PK-L
DS-PK-LRT
12 keys: 0 to 9, *, #
8 keys: Project/Query/Bypass/One-push to arm/Fire/Panic/Scroll up/Scroll down
Fault(Orange), Network(Green), Alarm(Red), Armed/Disarmed(Blue), Set(Res/Green dual color)
LCD
N/A
N/A
N/A
Two-way keyfob
1
1
1 debugging port
buzzer
N/A
Support
12 V, 0.15 A
1.8 W
-10 °C to +55 °C
10% to 90%
164 mm × 124 mm × 31 mm
272 g
3
a
164.13 mm
30.96 mm
Scan the following QR
Hybrid control panel does not support Z1, GND,
code to get
programming manual of
NO/NC, COM.
Hybrid control panel:
Control Panel
D- D+ 12V GND
Scan the following QR
code to get
programming manual of
control panel:
3
D- D+ 12V GND
c
GANGBOX MOUNTING
b
WALL MOUNTING
UD15865B
2
E.G
1 2 3 4 5
Lowbit
Highbit
BIN=00010
DEC=2