Diagram Reference
Components and Beeps
1
Alarm Keypad
Indicator
Zone
Product Information
COPYRIGHT ©2019 Hangzhou Hikvision Digital Technology
Run
Co., Ltd.
ALL RIGHTS RESERVED.
Any and all information, including, among others, wordings,
Armed/
pictures, graphs are the properties of Hangzhou Hikvision
Disarmed
Digital Technology Co., Ltd. or its subsidiaries (hereinafter
referred to be "Hikvision"). This user manual (hereinafter
Key
referred to be "the Manual") cannot be reproduced,
Buzzer
changed, translated, or distributed, partially or wholly, by
One Beep
any means, without the prior written permission of
Two Beeps
Hikvision. Unless otherwise stipulated, Hikvision does not
Five Beeps
make any warranties, guarantees or representations,
Continuous Beeping For Two Seconds
express or implied, regarding to the Manual.
Slowly Continuous Beeps
About this Manual
This Manual is applicable to Alarm Keypad.
Rapidly Continuous Beeps
The Manual includes instructions for using and managing
the product. Pictures, charts, images and all other
information hereinafter are for description and explanation
Rapid Beeps
only. The information contained in the Manual is subject to
Three Long Beeps and Two Short Beeps
Keypad Address Settings
change, without notice, due to firmware updates or other
2
reasons. Please find the latest version in the company
Configure the address via DIP switch of the keypad before powering on the
website (http://overseas.hikvision.com/en/).
system. The address should be in the range of 0 to 31. The binary value shown in
Please use this user manual under the guidance of
the diagram is 00010, which means the decimal value is 2. So the address of the
professionals.
keypad is 2.
Keypad Wiring and Installation
Trademarks Acknowledgement and other
3
a. Dimension
Hikvision's trademarks and logos are the properties of
b. Wiring
Hikvision in various jurisdictions. Other trademarks and
Route the cables through the cable hole of the rear panel, and connect the
logos mentioned below are the properties of their
cables to the corresponding terminals.
respective owners.
c. Install Keypad
1. Loosen the screw on the bottom of the keypad.
This product and - if applicable - the supplied
2. Open the front cover of the keypad.
accessories too are marked with "CE" and comply
3. Secure the rear panel on the wall with supplied screws.
therefore with the applicable harmonized European
standards listed under the RE Directive 2014/53/EU,
4. Close the front cover and tighten the screw on the buttom of the keypad to
the EMC Directive 2014/30/EU, the LVD Directive
complete the installation.
2014/35/EU, the RoHS Directive 2011/65/EU.
Keypad Operation Commands
4
The Input voltage should meet both the SELV (Safety
Function
Extra Low Voltage) and the Limited Power Source
according to the IEC60950-1 standard. Please refer
to technical specifications for detailed information.
Arming/Disarming
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or
Bypass
dispose of it at designated collection points. For
more information see: www.recyclethis.info
Clearing alarm
Legal Disclaimer
Partition
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW,
Keypad settings
THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE
AND FIRMWARE, IS PROVIDED "AS IS", WITH ALL FAULTS AND
Testing
ERRORS, AND HIKVISION MAKES NO WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING WITHOUT LIMITATION,
Panic alarm
MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A
Panic alarm
PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD
Wireless device
PARTY. IN NO EVENT WILL HIKVISION, ITS DIRECTORS,
enrollment
OFFICERS, EMPLOYEES, OR AGENTS BE LIABLE TO YOU FOR
ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT
DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR
RS-485 wired
LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR
device
LOSS OF DATA OR
Specification
DOCUMENTATION, IN CONNECTION WITH THE USE OF THIS
PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES.
REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE
USE OF PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS.
HIKVISION SHALL NOT TAKE ANY RESPONSIBILITES FOR
Interfaces &
ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER
components
DAMAGES RESULTING FROM CYBER ATTACK, HACKER
ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY
RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY
TECHNICAL SUPPORT IF REQUIRED.
SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK
Electrical &
ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING
THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE
CONFORMS THE APPLICABLE LAW. HIKVISION SHALL NOT BE
LIABLE IN THE EVENT THAT THIS PRODUCT IS USED WITH
ILLEGITIMATE PURPOSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL
AND THE APPLICABLE LAW, THE LATER PREVAILS.
Off:
Zone works properly
Solid Red:
Zone fault
Flashing Red:
Zone alarm
Solid Green:
Zone bypass
Solid Green:
System works properly
Flashing Green:
Under programming mode
Flashing Orange:
System fault
Solid Green:
Partition disarmed
Flashing Green:
Under programming mode
Partition armed
Solid Red:
Under walk test mode
Status
Project
Bypass
Panic
Pressing keys/command timed out or too long.
Valid command/Report uploaded.
Invalid command/Failed to upload the report in 60s.
Fault prompt (an additional beep
represents an increased fault) .
In the Entry/Exit delay status, the Delay zone armed,
or 2 min before auto arming/disarming starting.
In the Entry/Exit delay status, the Delay zone
triggered, or 1 min before auto arming/disarming
starting.
Zone alarm/keypad not registered.
Keypad tampered.
It is required to insert the screw for tamper alarm.
Description
Command
Normal (Away) arming/disarming
[Password] [#]
Stay arming
[Password] [*] [4] [#]
All Partition away arming
[Password][Project] [#]
All Partition stay arming
[Password] [*] [4] [Project] [#]
All partition disarming
[Password] [*] [Project] [#]
(hybrid control panel only)
[Password][Bypass][n] [n] [n] [#]
Bypass zone(n)
[Bypass][n][n][n][#]
nnn is the zone No.
Clearing under arming status
[Password] [*][1][#]
Enter partition settings page
[*][3][Partition No.][#]
Exiting partition settings page
[*][#]
Enabling/Disabling keypad tone
[*][5][1][#]
Walking testing
[Password][*][6][0][#]
Exiting walking testing
[Password][*][6][2][#]
Panic
[Panic]
[Password][project][operation][Device
Type][RS-485 Address][#]
Wireless device enrollment
Operation:1-enroll, 2-delete
(hybrid control panel only)
Device type: 02-detector, 03-repeater
04-output expander,05-siren
RS-485 Address: 0 to 21, 2 bits
Delete the selected RS-485 wired
[Password][*][project][RS-485
device(hybrid control panel only)
Address][#]
Model
DS-PKG-H4L
DS-PKG-H8L
Status indicator
2, Work (red and green) and arming/disarming (red and green)
4,
8,
Zone indicator
red and green
red and green
TAMPER switch
1
RS-485 interface
1
Serial port
1, for debug
Buzzer
1
Numeric key
12(0~9,*,#)
Screen
LED
Function key
4(Project, panic, status, bypass)
Arming, disarming, alarm clearing, bypass, bypass restoring,
Function
Function
partition control, control panel status query etc.
Power
12 VDC, 0.25A
Battery
Consumption
3W
Operation
-10℃ to+55℃
Temperature
Operation
10% to 90%
Others
Humidity
Dimension
133.9 mm (5.3") x 74.9 mm (1.9") x 27.7 mm (1.1" )
(W x H x D)
Weight
149g
1
3
74.9mm
Scan the following QR
code to get
programming manual of
a
Hybrid control panel:
Scan the following QR
code to get
programming manual of
network control panel:
3
b
Control Panel
D- D+ 12V GND
D- D+ 12V GND
2
27.7mm
c
1
3
E.G
1 2 3 4 5
Lowbit
Highbit
00010
DEC=2
2
4