2.2.2 RS485 ADDRESS
2.2.2.1 RS485 ADDRESS
For data downloading via RS485, please refer to the wiring
diagram on page 100
For connection to module SK9020, please refer to the
wiring diagram on page 100
1. Access programming mode, see page 17.
2. Select:
settings/system
address/RS485 address.
3. Enter the RS485 address (max. 3 digits).
RS485 ADDRESS
SCROLL
ESC
4. Confirm.
2.3. Select language
This menu can be used to set the main language.
1. Access programming mode, see page 17.
2. Select: settings/select language.
SELECT LANGUAGE
ITALIANO
*ENGLISH
FRANCAIS
OK
SCROLL
3. Select the desired language.
4. Confirm.
2.4. Second language
Allows the alternate switching of name directory standby messages
from the main language to the second language.
1. Access programming mode, see page 17.
2. Select: settings/second language.
3. Select the desired second language and confirm.
SCEGLI LINGUA
*ITALIANO
ENGLISH
FRANCAIS
OK
SCORRI
DEFAULT = Second language disabled.
To disable the second language:
1. Access programming mode, see page 17.
2. Select: settings/second language.
3. Select DEFAULT and confirm.
or:
Re-set the main language (see "2.3 Language").
IMPORTANT: If entered, the initial welcome message (see
section "2.8 Initial message") will not be switched to the second
language
The second language must be set after the main language has
been selected
24 24
parameters/RS485
000
OK
CANC
OK
ESC
OK
ESCI
2.5. Call management
Allows setting of the system type (Simplebus or Simplebus Top)
and call mode (Standard, indirect code, Immotec or Immotec
indirect).
CAUTION: set the system type (Simplebus or Simplebus Top)
and only afterwards the call mode (Standard, Indirect code,
Immotec standard or Immotec indirect)
To change the system type and call mode it
is necessary to erase the entire directory, see
"1.1.3 CLEAR ALL NAMES
(default) for systems without switching devices
SIMPLEBUS
Art. 1424 in Top 1, 2, 3 mode (see FT SB 21) which define
the system zones.
for systems with switching devices Art. 1424
SIMPLEBUS TOP
in Top 1, 2, 3 mode (see FT SB 21) which define the system
zones.
STANDARD - SIMPLEBUS (default)
In this mode, the user is identified by a name field and a code field
no longer than 3 digits (between 1 and 240).
Example:
User name= Mario Rossi
Code= 2
STANDARD - SIMPLEBUS TOP
In this mode, the user is identified by the name field (optional) and
a code field consisting of two parts:
zone field with no more than 3 digits (between 1 and 500);
user field which must have 3 digits (between 1 and 240).
Example:
User name= Mario Rossi
Code= 25 015
The call can be made in the following ways:
√ During normal operation
1. Enter the user code (e.g. 25 015).
2. Press
to make the call or
CALL USER
_25 015
CALL
or:
1. Scroll through the directory using
2. Press
to make the call or
INDIRECT CODE - SIMPLEBUS or SIMPLEBUS TOP
In this mode the user is identified by a name field (optional), a code
field (different for Simplebus and Simplebus Top) and an indirect
code with no more than 6 characters.
Example:
User name= Mario Rossi
Code= 2 (for Simplebus) or 25 015 (for Simplebus top)
Indirect code= 100
"
to cancel and exit.
CANC
.
to exit.