INSTALLATION OF SUCTION HOSE
Slide the suction hose into the connection socket (4), turn clockwise and gently pull back (fig. J).
Connect the other end of the suction hose to telescopic pipe.
Deinstallation of the suction hose is similar to installation, only the sequence of actions is reversed.
INSTALLATION OF TELESCOPIC PIPE AND ATTACHMENTS
Push the suction hose connection to the telescopic pipe holder so the latches snap in place.
Move the slider (e) down and extend the telescopic pipe to desired length (fig. K).
Put appropriate attachment onto telescopic pipe.
Floor attachments are especially useful for cleaning large areas and in wet operation mode. Crevice attachment
is suitable for cleaning edges, corners and crevices.
INSTALLATION OF UPPER HOOK FOR POWER CORD
Push the upper hook for power cord (12) into hole in the upper body (7) (fig. L).
SWITCHING ON / SWITCHING OFF
The mains voltage must match the voltage specified on the rating plate of the vacuum cleaner.
Vacuum cleaner features 3-position switch (8). Depending on the work performed, set the switch in
appropriate position (fig. M).
Pos I = (upper position of the switch) – device operates like regular vacuum cleaner.
Pos 0 = (middle position of the switch) – switched off.
Pos II = (bottom position of the switch) – vacuum cleaner can only be used with external device (power
tool) connected to power socket of the vacuum cleaner.
EXTRACTION OF DUSTS AND SHAVINGS PRODUCED DURING POWER TOOL OPERATION
Place the pleated filter (b) and/or dust bag on the vacuum cleaner.
Connect power tool plug in the power supply socket (2) (power consumption of the connected power
tool must not exceed 2000 W) (fig. N).
Switch on the vacuum cleaner – press the switch (8) to pos. II.
In this mode of operation vacuum cleaner can only be used with power tool connected. Remember
that the vacuum cleaner will be switched on automatically (with short delay) by power tool
connected to the socket.
Vacuum cleaner socket can be used only for purposes specified in this instruction manual.
When collecting gypsum dust, you must use both pleated filter and dust bag.
WET OPERATION
Do not use the vacuum cleaner to suck off flammable or explosive liquids, such as petrol, oils,
alcohols, solvents etc. and hot or glowing dusts and materials.
Foam membrane filters out large contaminations from liquids.
Release fixing clamps (3) on both sides of the device and remove upper body (7).
Remove pleated filter (b) and/or dust bag.
Empty the tank from dirt.
Ensure the float (f) can elevate in its ring in straight line (g) (fig. O).
Put foam membrane (h) onto the ring (g) of the float (f) (fig. P).
Install upper body (7) and secure with fixing clamps (3).
When water reaches its maximum allowable level in the tank, sound produced by motor changes
noticeably. Switch off the vacuum cleaner immediately and empty the tank.
EMPTYING DIRTY WATER FROM THE TANK
Place tray or other vessel and unscrew the drain plug (9) (fig. R).
Once the water has been drained screw in the drain plug (9).
OPERATION / SETTINGS
17