SAVE THESE INSTRUCTION-This manual contains important instructions that should be followed
This UPS utilizes voltage that may be hazardous. Do not
attempt to disassemble the unit. The unit contains no user
replaceable parts. Only factory service personnel may
perform repairs.
This pluggable type A equipment with battery already installed
by the supplier is operator installable and may be operated by
laymen.
The mains socket outlet that supplies the UPS shall be installed
near the UPS and shall be easily accessible.
During the installation of this equipment it should be assured
that the sum of the leakage currents of the UPS and the
connected loads does not exceed 3.5mA.
Connection to any other type of receptacle other than a
two-pole, three-wire grounded receptacle may result in shock
hazard as well as violate local electrical codes.
In the event of an emergency, press the "OFF" button and
disconnect the power cord from the AC power supply to
properly disable the UPS.
Do not allow any liquids or any foreign object to enter the UPS.
Do not place beverages or any other liquid-containing vessels
on or near the unit.
This unit intended for installation in a controlled environment
(temperature controlled, indoor area free of conductive
contaminants). Avoid installing the UPS in locations where
there is standing or running water, or excessive humidity.
Do not plug the UPS input into its own output.
Do not attach a power strip or surge suppressor to the UPS.
Do not attach non-computer-related items, such as medical
equipment, life-support equipment, microwave ovens, or
vacuum cleaners to UPS.
Do not dispose of batteries in a fire as they may explode.
Internal battery voltage is 12VDC.Sealed, lead-acid, 6-cell
battery.
MODEL
CAPACITY
Input Voltage
Input Voltage Range
Output Voltage
Regulation
Transfer Time
Waveform
Battery Type
Battery Number
Charging Time
Dimension (DxWxH)mm
Net Weight (kgs)
Humidity
Noise Level
*Specifications are subject to change without notice.
during installation and maintenance of the UPS and batteries.
400
600
400VA/
600VA/
240W
360W
220/230/240 VAC
180-270 VAC
± 10 % (Bat. mode)
Typical 2-6 ms
Simulated Sine Wave
12V/4Ah
12V/4.5Ah
1
1
8
hours recover to 90% capacity
305 x 158.5 x 95
2.5
2.6
0-90% RH @ 0-40°C non-condensing)
Less than 40dB
A battery can present a risk of electrical shock and high short
circuit current. The following precautions should be observed
when working on batteries:
1) Remove watches, rings, or other metal objects from the hands.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or
disconnecting batteries terminal.
Servicing of batteries should be performed or supervised by
personnel knowledgeable of batteries and the required
precautions. Keep unauthorized personnel away from
batteries.
When replacing batteries, replace with the same number and
type of sealed lead-acid battery.
Do not open or mutilate the battery or batteries. Release
electrolyte is harmful to the skin and eyes. It may be toxic.
Attention, hazardous through electric shock. Also with dis-
connection of this unit from the mains, hazardous voltage still
may be accessible through supply from battery. The battery
supply should be therefore disconnected in the plus and minus
pole at the connectors of the battery when maintenance or
service work inside the UPS is necessary.
To reduce the risk of overheating the UPS, do not cover the
UPS' cooling vents and avoid exposing the unit to direct
sunlight or installing the unit near heat emitting appliances such
as space heater or furnaces.
Unplug the UPS prior to cleaning and do not use liquid or spray
detergent.
WARNING: This is a category C2 UPS product. In a residential
environment, this product may cause radio interference, in
which case the user many be required to take additional
measures.
Problem
800
800VA/
Nothing is
480W
displayed on
the panel.
The UPS
always on
battery mode.
12V/5Ah
1
The UPS
continuously
beeps.
2.9
Backup time
too short.
If any abnormal situations occur that are not listed above, please
call for service immediately.
Standby UPS
400VA/600VA/800VA
Possible Cause
The UPS is not on.
Press the power switch
again to turn on the UPS.
Battery voltage is too
Charge the battery at least
low.
6 hours.
Battery fault.
Replace the battery.
Power cord loose.
Re-plug the power cord.
Please check the fault
Please check the fault code
code for the details.
for the details.
Battery voltage is too
Charge the battery at least
low.
6 hours.
Overload.
Remove some unnecessary
loads. Before reconnecting
equipment, please verify
that the load matches the
UPS capability specified in
the specs.
Battery defect.
Replace the battery.
Solutions