EQUYSIS EF-D34 Manual Del Usuario página 41

Tabla de contenido

Publicidad

0x1010
Measuring Status
0x1010
4112
PFC_FlowTotal_FRAM_FWD_VAL-High
0x1011
4113
PFC_FlowTotal_FRAM_FWD_VAL+1
0x1012
4114
PFC_FlowTotal_FRAM_FWD_VAL+2
0x1013
4115
PFC_FlowTotal_FRAM_FWD_VAL-Low
0x1014
4116
PFC_FlowTotal_FRAM_REV_VAL-High
0x1015
4117
PFC_FlowTotal_FRAM_REV_VAL+1
0x1016
4118
PFC_FlowTotal_FRAM_REV_VAL+2
0x1017
4119
PFC_FlowTotal_FRAM_REV_VAL-Low
0x1018
4120
PFC_FlowTotal_FRAM_BI_DIR_VAL-High
0x1019
4121
PFC_FlowTotal_FRAM_BI_DIR_VAL+1
0x101A
4122
PFC_FlowTotal_FRAM_BI_DIR_VAL+2
0x101B
4123
PFC_FlowTotal_FRAM_BI_DIR_VAL-Low
0x101C
4124
PFC_FlowRate_Main_Val-High
0x101D
4125
PFC_FlowRate_Main_Val+1
0x101E
4126
PFC_FlowRate_Main_Val+2
0x101F
4127
PFC_FlowRate_Main_Val-Low
0x1020
4128
gb_pfc_flowrate_rawdata_m_s-High
0x1021
4129
gb_pfc_flowrate_rawdata_m_s+1
0x1022
4130
gb_pfc_flowrate_rawdata_m_s+2
0x1023
4131
gb_pfc_flowrate_rawdata_m_s-Low
0x1024
4132
gf_pfc_current_out_value-High
0x1025
4133
gf_pfc_current_out_value-Low
0x1026
4134
PFC_SIMULATION_INPUT_CURR-High
0x1027
4135
PFC_SIMULATION_INPUT_CURR-Low
0x1028
4136
gb_pfc_liquid_resistance-High
0x1029
4137
gb_pfc_liquid_resistance-Low
0x102A
4138
PFC_FlowTotal_FWD_VAL-Low
0x102B
4139
PFC_FlowTotal_FWD_VAL-High
0x102C
4140
PFC_FlowTotal_REV_VAL-Low
0x102D
4141
PFC_FlowTotal_REV_VAL-High
0x102E
4142
PFC_FlowTotal_BI_VAL-Low
0x102F
4143
PFC_FlowTotal_BI_VAL-High
0x1030
4144
PFC_Flowrate_Main_Vluae-Low
0x1031
4145
PFC_Flowrate_Main_Vluae-High
0x1032
4146
PFC_Flowrate_rawdata_vluae-Low
0x1033
4147
PFC_Flowrate_rawdata_vluae-High
MANUAL - MEDIDOR ELECTROMAGNÉTICO
Data Type Unit Range
FLOAT64
FLOAT64
FLOAT64
Rate
FLOAT64
Unit
FLOAT64
m/s
FLOAT32
mA
FLOAT32
mA
FLOAT32
UINT32
Liter
UINT32
Liter
UINT32
Liter
Rate
FLOAT32
Unit
FLOAT32
m/s
www.equysis.com
Definition
Authority
Read only
Forward accumulated
Read only
flow capacity
Read only
Read only
Read only
Read only
Backward accumulated
flow capacity
Read only
Read only
Read only
Read only
Two-way accumulated
flow capacity
Read only
Read only
Read only
Read only
Instant flow rate value
Read only
Read only
Read only
Read only
\Setting\ Information\
Actual flow rate
Read only
Read only
Read only
Output current value
Read only
Read only
Iutput current value
Read only
Read only
\Setting\ Information\
Liquid resistance value
Read only
Read only
Forward accumulated
flow capacity
Read only
Read only
Backward accumulated
flow capacity
Read only
Read only
Two-way accumulated
flow capacity
Read only
Read only
Instant flow rate value
Read only
Read only
\Setting\ Information\
Actual flow rate
Read only
41