Automatic Loading Of Screw; Lighting The Stove; Switching On The Stove; How To Associate The Remote Control To The Stove - Ravelli BOX LINE Serie Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

N.B.: The number indicated while changing the parameters
refers only to a percentage value that acts on the default
parameters set in the electronic board.
In any case, these values must be changed if bad combustion
arises due to the purchase of different pellets from those used
when the stove was tested.
!
!
THIS FUNCTION IS EFFECTIVE ONLY IF. THE DUE
REGULATIONS HAVE BEEN MADE DURING THE IN-
SPECTION OF THE STOVE
9.6. Automatic loading of the screw
To automatically load the screw (when the stove is new the loading
screw is empty), proceed as follows:
1. Remove and reset the electric supply of the stove using the general
switch on the back.
2. The display will show FINAL CLEANING and then OFF.
3. Press button P7, CLOCK SETTING MENU will appear.
4. Press button P6: "SCREW 0" will appear.
PRESS BUTTON P2 TO ACTIVATE AND P1 TO DEACTIVATE THE
SCREW
Repeat the operation several times until you can see the pellets fall
into the fire pot.
N.B.: This operation can be performed only if the stove is
OFF.
!
!
AFTER HAVING LOADED THE SCREW, EMPTY THE
FIRE POT INTO THE TANK BEFORE SWITCHING ON.

9.7. Switching on the stove

Before switching on the stove, proceed as follows:
1. Insert the mains supply cable and activate the switch behind the
stove's right-hand rear upright (see Fig. A).
The draught value is modified with keys P4
and P5 .The quantity of pellet used (the value
indicated during the change only indicates a
percentage value that acts on the default pa-
rameters set in the electronic board) can be
measured with keys P1 and P2.
THE SCREW IS IDLE
SCREW ACTIVATED
Fig. A
2. Place the switch on the back in position 1.
3. Check that the appliance is connected to the flue.
4. Load the tank (see par. 3.4).
5. Load the screw (see par. 9.5).
6. Press button P3 for 3 seconds.
At this point the stove will switch on.
The following messages will appear on the screen
LIGHT
WAIT FOR FLAME
FLAME PRESENT
WORKING
During the working phase, the following settings should be checked:
POWER SETTING
ROOM TEMPERATURE SETTING as described in chapter 9.3
PELLET/AIR MIX SETTING

9.8. How to associate the remote control to the stove

All input stoves are fitted with remote-control, radio-wave handsets
and a receiver located on the right-hand side of the stove. Some-
times, due to interference from other electrical household appliances
(microwave ovens, satellite decoders, mobile phones, cbs, .... ) the
connection between the stove and the handset may be interrupted
(no field). The following operations must be carried out to reinstate
the connection:
Switch the stove off.
Unplug the power lead.
Press the triangle keys 1 and 2 on the handset together for
about 3 seconds.
Using triangle key 2, select the frequency unit to be loaded
(select unit 0 , 1 , 2 , 3 ).
Reconnect the electricity by plugging in the power lead.
Press the red button.
If the operation is successful, UNIT LOADED 0, 1, 2, 3 will appear
on the handset.

9.9. Synthetic table of phases

PHASE
DESCRIPTION
FINAL CLEANING
The stove is switching off, the cooling phase is not yet completed
The glow-plug pre-heating phase has started, and the pellet starts to fall into the
LIGHT
re pot.
WAIT FOR FLAME
The pelle is ligted by the hot air passing trought the ignition candle
FLAME PRESENT
The pellets are loaded into the re pot
WORK
The ame is visibile in the re pot
MODULATION
The ame is visible in the re pot
WORKING
ECO STOP
The room temperature set has been reached
T ON
Comfort Climate activated, temperature set has been reached, the stove is off.
FAN WAITING FOR
The room sensor is off or an external thermostat has been connected
START
FAN WAITING FOR
The stove is in the cooling DOWN:when stove is cooled down can start
RESTART
automatically.
LIGHT WAITING FOR
The switch ON when the dtove is warm started. The operation is same of phase ON
RE-IGNITION
The max temperature of smokes is reached: to reducefeeding pellets and air draft
HOT SMOKE
at PT 01
OFF
The stove is off
!
!
IF THE "HOT SMOKE" SIGNAL IS DISPLAYED THIS
MEANS THAT THERE ARE PROBLEMS IN THE COM-
BUSTION AND THEREFORE YOU MUST CONTACT
YOUR LOCAL T.A.C. FOR ASSISTANCE.

10. MAINTENANCE

Before carrying out any maintenance operation on the stove, please
take the following precautions:
Make sure that all the parts of the stove are cold
Make sure that the ashes are completely extinguished
Make sure that the general switch is in the zero position (off)
Make sure that the plug is disconnected from the socket, thus avoid-
ing accidental contacts
as described in chapter 9.1
as described in chapter 9.4
Pag.23

Publicidad

Tabla de contenido
loading