SICK PLS 10X-317 Manual De Instrucciones página 164

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 59
PLS
Properties
Switching voltage
HIGH active (U
)
eff
at U
= 16.8 V
v
Voltage LOW
Switching current
(referred to EXT_GND)
Time behaviour of output
without restart inhibit
Activation on protective field (SF) clear
Time behaviour of output
after 2 seconds
Activation on protective field (SF) clear
Short-circuit protected
Fault: Leak current
Fault: Interruption of GND cable.
The downstream control element
must recognise this status as LOW.
Pure load capacity
Switching frequency
Pure load inductivity
At low switching frequencies the max.
permissible load inductivity is higher.
164
8 009 810/OA87/13-09-04 Operating Instruction • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved
Data
min.
type
13.4 V
0 V
4 mA
Depends on scan rate
190 ms
Depends on scan rate
2 s
by monitoring of outputs
GB
max.
2.5 V
150 mA
2.1 mA
100 nF
3 Hz
2H