Team kalorik TKG SIS 1000 Manual De Instrucciones página 17

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
Fax +32 2 359 95 50
in the water tank, immerse it in water for some time before using the appliance again in
order to obtain a better performance.
To buy a new cartridge, please contact the nearest customer service.
Never use the appliance without anti-scale cartridge!
CLEANING
The plastic parts of the appliance can be cleaned with a damp cloth.
To clean the soleplate of the iron, you will find specific products in the shops. Please also
read the instructions of use. Never use abrasive products to clean it.
Never immerse the appliance in water or any other liquid.
TROUBLE-SHOOTING
Problem
Iron will not heat
No steam is being
produced when the
steam button is pressed
Power light
blinks quickly
and a beep sounds; the
buttons don't work
PROTECTION OF THE ENVIRONMENT – DIRECTIVE 2002/96/EC
In order to preserve our environment and protect human health, the waste electrical and
electronic equipment should be disposed of in accordance with specific rules with the
implication of both suppliers and users. For this reason, as indicated by the symbol
rating label or on the packaging, your appliance should not be disposed of as unsorted
municipal waste. The user has the right to bring it to a municipal collection point performing
waste recovery by means of reuse, recycling or use for other applications in accordance with
the directive.
Copies of the I/B. Please reproduce them without any
changes except under special instruction from Team
International BELGIUM. The pages must be reproduced
and folded in order to obtain a booklet A5 (+/- 148.5 mm
width x 210 mm height). When folding, make sure you
keep the good numbering when you turn the pages of
the I/B. Don't change the page numbering. Keep the
language integrity.
Possible causes
Incorrect connection to the
mains
Handle is not down
Switch is in position
Unknown malfunction
Switch is in NYLON position
No water in water tank
Anti-calc cartridge has not been
installed properly
Water tank has not been
installed correctly
Defect of the internal circuit, the
appliance has turned into the
self-protection mode
17
Assembly page 17/72
Solution
Unplug and replug to the
mains
Lay the handle down
Select the desired
temperature setting
Take the appliance to a
qualified technician for
examination and repair
Select the desired
temperature setting
Fill water into the water tank
Install the cartridge correctly
Slide the water tank into the
base until you hear a click
Unplug, let cool down and
restart the appliance; if it still
does not function, take it to a
qualified technician for repair
on the
TKG SIS 1000 - 081224

Publicidad

Tabla de contenido
loading

Tabla de contenido