English
General warnings
• Read instructions carefully, before beginning installation and per-
form any jobs as specified by the manufacturer;
• Installing, programming, setting up and maintaining the product
must only be done by skilled technical staff that is specifically trai-
ned to comply with current safety and packaging disposal regula-
tions and standards.
• Before performing any cleaning or maintenance, cut the main
power to the device;
• The device must be used only for the specific purpose for which it
was expressly designed.
• The manufacturer may not, in any way, be liable for any damage
deriving from improper, wrongful or unreasonable use.
IMPORTANT NOTICE
This product is a combination of a CAME product and third-party
products integrated by CAME.
Distributors and end users of this product may not in any way
change or reproduce this Product, its documentation, trademar-
ks, copyright or other wording relevant to the product; nor may
they use the product or its components in applications other than
CAME systems.
Distributors and end users must comply with the rules and regu-
lations regarding any type of use of this product, therein inclu-
ding its export.
Technical data
Type
Power supply [V DC]
Absorbed current at 18 V DC [mA]
Absorbed current at 14 V DC [mA]
Stocking temperature [°C]
Operating temperature [°C]
Protection rating [IP]
8
Functions
B
Connectors
USB: Memory key connector, reserved for future use;
CN2: Reserved for future use;
PORT0: Ethernet port 10/100Mb;
PORT1: Ethernet port 10/100Mb;
Terminal boards
+
Power supply
12-24 V DC
–
+D
CANBUS (reserved for future use)
–D
C
reserved for future use
I1
I2
Reserved for future use
I3
–
TX–
TX+
Serial interface 422
RX–
RX+
Jumper
SW4 serial type selection
ETI/Domo XIP
12-24
220
285
-25 / +70 °
For 422 serial selection
0 / +35 °
30
SW1: CAN DATA (reserved for future use);
SW3: Restore factory configuration;
RESET button: restarting the device
LED
Reference
"STAT"
Installing
The device must installed on a DIN (EN50022) guide inside a corre-
sponding electrical panel. For the overall dimensions please see figure
A
NOTE. Make sure the device is properly ventilated if it is encased
in metal.
Initiation
The ETI/Domo XIP interface features two configurable Ethernet ports:
For 485 serial selection
'Switch' or 'Dual Network' .
(for future use)
You can connect up a PC directly to one of the two ports without using
a Cross cable. Once the interface is powered up, wait until the LEDs go
into 'normal functioning' mode (see table).
Once the cable is connected and the PC configured to con-
LED
Color
Switching on meaning
Blu
Device status
STAT
Green
Activity underway
ACT
"ACT"
Flashing meaning
Normal functioning: software uploading
phase
Normal functioning: software running
Device in maintenance phase: UNINTER-
RUPTIBLE OPERATION
Execution program: UNINTERRUPTIBLE
OPERATION
Right after powering up in normal functio-
ning mode or if prolonged anomalous fun-
ctioning: device blocked
= Off
= On
= Slow flashing
= Quick flashing
A
.